TC66N-620 TOPCon Solar Module product image
TOPCon Solar Modules620 W

Solar module evidence review

TC66N-620 TOPCon module: Verify Electrical, Mechanical and Document Scope

This page organizes the current catalogue identity for the TC66N-620 TOPCon module. The visible source establishes 620 W / 66-format title route, but does not supply a released exact-model electrical table, BOM, load report or certificate package. Treat it as a controlled RFQ shortlist rather than a released module specification.

Current source identity: 620 W / 66-format title route. No model-specific released datasheet is attached to this catalogue record.

Catalogue route: 620 W / 66-format title routeElectrical evidence: Exact STC/NOCT table requiredMechanical evidence: Exact dimensions, mass, clamp and load data requiredDocument boundary: No released model-specific factory package attached
Build Your RFQ

Current Source Specification Tables

These tables reproduce the current catalogue or attached datasheet record. Confirm the exact model identity, production revision and destination-specific documents before order release.

Electrical Characteristics (STC)

ModelTC66N-620
Maximum power (Pmax)620 W
Maximum power voltage (Vmpp)41.1 V
Maximum power current (Impp)15.09 A
Open-circuit voltage (Voc)49.3 V
Short-circuit current (Isc)15.96 A
Module efficiency23.0%
Power tolerance0 to +5 W
Bifaciality80% ± 5%
STC1000 W/m², 25°C cell temperature, AM 1.5

Mechanical Characteristics

Cell technologyN-type i-TOPCon monocrystalline, bifacial dual-glass
Cell configuration132 half-cells
Module dimensions2382 × 1134 × 30 mm
Weight33.7 kg
Front / rear glass2.0 mm heat-strengthened glass / 2.0 mm heat-strengthened glass
FrameAnodized aluminium alloy
Junction boxIP68
ConnectorMC4-compatible; final connector subject to approved datasheet

Operating Conditions

Operating temperature-40°C to +85°C
Maximum system voltage1500 V DC
Maximum series fuse rating30 A
Nominal operating cell temperature43°C ± 2°C
Temperature coefficient of Pmax-0.29% / °C
Temperature coefficient of Voc-0.24% / °C
Temperature coefficient of Isc+0.04% / °C
Mechanical loadRefer to the approved production-batch datasheet

Packing Configuration

Reference packing36 modules / pallet; 720 modules / 40 ft HQ
Packing noteConfirm loading quantity and pallet dimensions before booking

Current document status

Request the exact datasheet/nameplate, manufacturer and factory identity, full suffix/BOM, STC/NOCT table, temperature coefficients, dimensions/mass, connector/cable, load/fire/PID evidence, certificates, warranty, flash/EL, packing and serial traceability before order release.

Current record

Use the model identity as a document-control key

Power and cell-format wording alone cannot establish electrical, mechanical or certification equivalence.

Exact model identity

The visible route is 620 W / 66-format title route. Confirm the complete suffix, manufacturer, factory and nameplate before quotation.

Electrical table missing

Request STC and NOCT Pmax/Vmpp/Impp/Voc/Isc, tolerance, temperature coefficients, maximum system voltage and series-fuse rating for this exact member.

Mechanical evidence missing

Request dimensions, mass, glass/frame/junction-box construction, connector/cable, clamp zones, static/dynamic load and installation orientation for the exact revision.

Production evidence missing

Require BOM, certificate/report coverage, fire/PID/load evidence, warranty, flash/EL criteria, packing drawing and serial traceability.

Module RFQ checks

Six checks before selecting this module

String fit, mounting and production documents must all refer to the same exact model and revision.

Identity and factory

Freeze manufacturer, factory, full suffix, nameplate and BOM against approved documents and sample.

String voltage

Use exact Voc, temperature coefficient and site minimum temperature with inverter maximum/start/MPPT voltage.

String current

Check exact Imp/Isc against inverter inputs, parallel strings, connectors, cables, fuses and design factors.

Mounting and loads

Confirm dimensions, mass, clamp zones, rail/tracker fit, orientation, roof/tracker geometry and wind/snow design.

Energy model

Use verified STC/NOCT, temperature, irradiance, mismatch, soiling, shading and any bifacial construction evidence; do not use the power label as field yield.

Documents and logistics

Request reports/certificates, warranty, flash/EL, packing, inspection criteria, serial traceability and shipment terms.

Evidence boundaries

A power-and-cell-format title is not a released module specification

Electrical compatibility, structure and certification depend on exact model documents and project design.

No cross-bin inference

Do not transfer electrical, size, current, load, connector, packing or warranty data from a neighbouring power bin or similar cell format.

STC is not field output

Field energy depends on irradiance, cell temperature, spectrum, mismatch, soiling, angle, shading and system losses.

Title labels are not certificates

TOPCon, back-contact, Black or bifacial wording does not establish factory, BOM, appearance, test report or destination approval.

Mounting needs load data

No project structural conclusion can be made without exact dimensions, clamp zones, load tests and installation instructions.

Continue the module review

Convert the catalogue route into an evidence-controlled RFQ

Use the existing guides to obtain the missing exact-model documents before selecting a supplier.

Module RFQ FAQ

Questions to close before batch approval

The delivered label and documents must map to one exact approved record.

Is TC66N-620 TOPCon module a released factory specification?

Not from the current catalogue record alone. It establishes the model route but needs a matching factory datasheet, nameplate, BOM and document package.

Can string design use the listed power and cell-format title?

No. Obtain exact Voc, Vmp, Isc, Imp, temperature coefficients, maximum system voltage and fuse information first.

Can a similar module share the same mounting design?

Not automatically. Verify exact dimensions, mass, frame, clamp zones, load tests and installation instructions.

Which files should be requested?

Request datasheet, nameplate, BOM, certificates/reports, load/fire/PID evidence, warranty, flash/EL, packing and traceability for the exact model.

Prepare a verified TC66N-620 TOPCon module RFQ

Send inverter/string design, mounting conditions, destination documents, sampling, packing and traceability requirements to evaluate the exact module.

Start with the product, application or project information you have. We can help identify the remaining configuration, document or delivery questions before a final quotation.

Verify Module Evidence

Related Products

TC54N-430 TOPCon Solar Module product image

TC54N-430 TOPCon Solar Module

Representative N-type TOPCon sourcing configuration for residential rooftops and space-constrained commercial roofs. Final electrical label, bill of materials, certification scope, packing, and delivery configuration must be confirmed against the selected production batch before purchase.

430 W21.5%108 half-cells
View Details
TC54N-455 TOPCon Solar Module product image

TC54N-455 TOPCon Solar Module

Representative N-type TOPCon sourcing configuration for high-efficiency residential and light-commercial rooftops. Final electrical label, bill of materials, certification scope, packing, and delivery configuration must be confirmed against the selected production batch before purchase.

455 W22.8%108 half-cells
View Details
TC72N-550 TOPCon Solar Module product image

TC72N-550 TOPCon Solar Module

Representative N-type TOPCon sourcing configuration for commercial rooftops and distributed ground-mount projects. Final electrical label, bill of materials, certification scope, packing, and delivery configuration must be confirmed against the selected production batch before purchase.

550 W21.3%144 half-cells
View Details
Chat with Us