MID 25-40KTL3-X
On-grid PV InverterCommercial & Industrial PV Inverter

Growatt commercial PV string-inverter review

Growatt MID 25-40KTL3-X Commercial String Inverter Family

MID 25/30/33/36/40KTL3-X The verified source tables show 1100 V maximum and 200-1000 V MPPT; 25/30/33 kW has three trackers, 36/40 kW has four, and every tracker lists two strings with 26 A operating current On the AC side, three-phase 220/380 or 230/400 V, 25-40 kW rated output and 27.7-44 kVA maximum apparent power 98.8% maximum Select one complete model, voltage route and destination document set before quotation; family maxima, optional protection and certificate lists do not apply automatically to every member.

Released members: MID 25/30/33/36/40KTL3-XPV route: 1100 V maximum and 200-1000 V MPPT; 25/30/33 kW has three trackers, 36/40 kW has four, and every tracker lists two strings with 26 A operating currentAC route: three-phase 220/380 or 230/400 V, 25-40 kW rated output and 27.7-44 kVA maximum apparent powerEnclosure and efficiency: IP66; 29.5 kg through 33 kW and 30.5 kg for 36/40 kW; 98.8% maximum
Build Your RFQ

Current source identity: official Growatt May 2026 MID 25-40KTL3-X EU datasheet set. The tracker count changes at 36 kW, and the source footnote states that AFCI needs activation after installation; neither condition should be generalized away.

Current document status

Before quotation, obtain the exact full model and suffix, current datasheet and manual, destination certificate/model schedule, approved grid profile, PV string schedule, AC collection and protection design, AFCI/PID/SPD option status, connector and monitoring hardware, firmware, warranty, packing and written substitution rules.

Current family evidence

Preserve the member, DC-input and AC-voltage boundaries

The official tables define a family, not one interchangeable column.

Released model columns

MID 25/30/33/36/40KTL3-X

PV and MPPT architecture

1100 V maximum and 200-1000 V MPPT; 25/30/33 kW has three trackers, 36/40 kW has four, and every tracker lists two strings with 26 A operating current

AC interconnection route

three-phase 220/380 or 230/400 V, 25-40 kW rated output and 27.7-44 kVA maximum apparent power

Protection and physical record

Type II DC/AC surge protection and string monitoring are listed; AFCI is shown with an installation-activation footnote. IP66; 29.5 kg through 33 kW and 30.5 kg for 36/40 kW

commercial PV inverter RFQ inputs

Six checks before fixing the inverter member and BOM

Array, AC collection, options and destination evidence must map to the same released model.

Full model and destination

State the complete model/suffix, quantity, country, utility, service voltage/frequency, export or PPC rule and required grid-code, safety and EMC evidence.

PV string and MPPT schedule

Provide module Voc/Vmp/Isc/Imp, temperature coefficients, strings per tracker and orientation; verify cold Voc, operating voltage, tracker current, short-circuit allowance and connector/cable ratings.

AC collection and grid

Define inverter AC voltage, conductor/busbar, breaker or switchgear, transformer where applicable, grounding, fault level, voltage drop, reactive-power duty and point-of-connection limit.

Protection and ordering options

Freeze DC switch, SPD, AFCI, anti-PID, night SVG or other options by exact ordering code. A source row marked optional or variant-specific is not standard equipment for every member.

Monitoring and plant control

Confirm RS485/USB, Wi-Fi/LAN/4G/RF/PLC hardware, logger or ShineMaster/SEM route, meter/PPC/export control, communications-loss behavior, firmware and account ownership.

Documents and commercial control

Request current datasheet/manual, certificate model list, SLD and settings, warranty, packing, serial traceability, accessories, lead time and written approval for any substitution.

Family, option and performance boundaries

Do not move family maxima or certificate coverage between columns

The exact member, voltage route, firmware, array and destination documents remain controlling.

Variant tables remain separate

The tracker count changes at 36 kW, and the source footnote states that AFCI needs activation after installation; neither condition should be generalized away.

Maximum efficiency is not yield

98.8% maximum This is a datasheet maximum, not an annual-energy or every-operating-point guarantee; model, loading, temperature, clipping, wiring and availability affect yield.

Optional protection needs an order code

Type II DC/AC surge protection and string monitoring are listed; AFCI is shown with an installation-activation footnote. Confirm factory option, external devices, settings, applicable manual and destination design instead of relying on a family headline.

Certificates do not transfer automatically

A downloads list may span members, suffixes and countries. Require the ordered full model on the current certificate schedule and use the destination grid settings and commissioning record.

Continue the commercial PV review

Connect the exact inverter to the project design and controlled BOM

Use the solution and BOM guides to coordinate electrical interfaces, documents and responsibility boundaries.

Growatt MID 25-40KTL3-X Commercial String Inverter Family FAQ

Questions to close before releasing the inverter order

One exact member and one matching evidence set should support the quotation.

Which model columns are covered by the verified source?

MID 25/30/33/36/40KTL3-X

Can one PV string design be used across the whole family?

No. 1100 V maximum and 200-1000 V MPPT; 25/30/33 kW has three trackers, 36/40 kW has four, and every tracker lists two strings with 26 A operating current Check the exact member's tracker/string allocation, voltage and current against the selected module and site temperature.

Are AFCI, PID and other protection functions standard on every member?

Do not assume that. Type II DC/AC surge protection and string monitoring are listed; AFCI is shown with an installation-activation footnote. Confirm the complete ordering code, external protection design, manual and destination requirements.

What should the RFQ freeze?

Freeze full model/suffix, PV strings, AC voltage and collection, transformer/grid interface, protection/options, monitoring/PPC, certificate set, firmware, warranty, accessories and quantity.

Prepare an exact Growatt MID 25-40KTL3-X Commercial String Inverter Family RFQ

Send the full member and suffix, module/string schedule, AC and grid design, protection/options, monitoring/control, destination documents, accessories and quantity.

Start with the product, application or project information you have. We can help identify the remaining configuration, document or delivery questions before a final quotation.

Verify the Inverter Configuration
Chat with Us