G125K-LE260 125kW / 261kWh Liquid-Cooled ESS Cabinet
Current source identity: G125K-LE260 exact model; displayed sources conflict on approximate system weight and do not provide a complete released AC-system BOM.
The G125K-LE260 record identifies a 261 kWh LFP cabinet with a 125 kW AC system class, 130.5 kW DC rated-power wording, an 832 V rated battery platform, 728–936 V range, 157 A standard charge/discharge current and liquid cooling. The current sources differ on approximate weight and do not establish usable AC energy, exact PCS/EMS/BMS BOM, auxiliary consumption, system efficiency, fire approval, grid code or warranty. Those items must be configuration- and project-specific.
- Model
- G125K-LE260
- Displayed system class
- 125 kW AC / 261 kWh nominal
- Displayed battery route
- 832 V rated / 728–936 V / 157 A
- Thermal/fire labels
- Liquid cooling / aerosol / temperature and smoke detection
Current source-derived specifications
These values are preserved from the current product record. Read them with the configuration, compatibility, document and project boundaries below before using them in a quotation.
Battery & Energy
| Nominal Energy | 261 kWh |
|---|---|
| Battery Platform | LFP 314 Ah; 1P260S configuration |
| Voltage | 728–936 V battery range; 832 V rated battery voltage |
| Battery Pack | 166.4 V, 314 Ah |
| Standard Charge / Discharge Current | 157 A / 157 A |
| Cycle Life | 8,000 cycles to 70% EOL at 90% DoD |
System & Installation
| System Type | Liquid-cooled commercial & industrial energy storage cabinet |
|---|---|
| Rated Power | 125 kW AC system class; 130.5 kW DC rated power stated |
| Cooling | Liquid cooling; 50% ethylene-glycol aqueous coolant stated |
| Protection | IP54; aerosol fire protection with temperature and smoke detection listed |
| Communication | Confirm PCS, EMS and site communication interface in final configuration |
| Dimensions | 970 × 1420 × 2320 mm |
| Weight | Approx. 2.6–3.0 t; source documents differ |
| Recommended Application | High-utilisation C&I storage, solar shifting and demand-charge management |
| Model Number | G125K-LE260 |
| DC Configuration | 1P260S |
| Charge / Discharge Rate | 0.5P |
| Operating Temperature | -20 to 50°C |
| Relative Humidity | ≤95% RH |
| Installation Altitude | <2,000 m |
| Detector Type | Temperature and smoke detection |
Current document status
Request the current cabinet datasheet/manual, exact PCS/BMS/EMS and battery BOM, one-line, usable-energy/RTE basis, liquid-loop data, fire detection/suppression design and approvals, grid certificates, transport plan, warranty and FAT/SAT documents.
Current cabinet evidence
Keep battery, AC-system and project-scope values separate
The exact model is known, but the complete delivered system and performance basis are not yet fixed.
Power and energy identity
The record combines 125 kW AC system-class and 130.5 kW DC rated-power wording with 261 kWh nominal energy. Confirm PCS rating and whether every value belongs to the same released configuration.
Battery architecture
LFP 314 Ah, 1P260S, 832 V rated, 728–936 V and 157 A are listed. Pack/rack composition, BMS hierarchy, usable energy and DC protection require the BOM and one-line.
Liquid cooling
A 50% ethylene-glycol aqueous coolant is stated. Loop volume, pump redundancy, leak detection, heat rejection, ambient derating, maintenance and site interface are missing.
Fire and physical record
Aerosol suppression plus temperature/smoke detection and IP54 are listed. Source weights differ around 2.6–3.0 t; final transport weight, lifting points, approval basis and fire interfaces need released documents.
G125K-LE260 project checks
Six workstreams before approving the cabinet configuration
A C&I cabinet quotation must define AC performance, usable energy, safety, site and service scope.
Duty and operating mode
Define peak shaving, solar shifting, backup/microgrid, cycles/day, power profile, required duration, reserve SOC and grid/export constraints.
Exact BOM
Request PCS, battery packs/racks, BMS, EMS/controller, HVAC/liquid loop, fire system, switchgear, meter, auxiliary supply and communication item numbers.
Performance basis
Confirm gross/usable DC and AC energy, continuous/peak kW, auxiliary load, RTE, efficiency curve, availability, degradation and ambient/altitude derating.
AC and grid interface
Provide voltage/frequency, fault level, earthing, point of connection, transformer if needed, protection study, grid code, meter/CT and export-control requirements.
Site and safety
Confirm foundation/floor load, access, clearances, drainage, coolant containment, noise, ventilation, fire separation, detection/suppression interface and emergency response.
Delivery and acceptance
Request transport/lifting data, FAT/SAT, commissioning, performance tests, training, spares, remote access, warranty, service SLA and handover documents.
Cabinet performance boundaries
261 kWh nominal and 125 kW class do not prove delivered AC service
Performance and safety claims must state the selected BOM, test conditions and responsibility boundary.
Nominal energy is not usable AC energy
Apply SOC window, DoD, cell/BMS limits, auxiliary cooling/fire loads, conversion losses, temperature and degradation.
Cycle count is condition-specific
The displayed 8,000 cycles to 70% EOL at 90% DoD needs test standard, C-rate, temperature, rest periods and a clear relationship to system warranty.
Fire-system labels are not site approval
Aerosol, smoke and temperature labels do not define detection zones, agent quantity, ventilation shutdown, code compliance, AHJ approval or emergency plan.
Liquid cooling is not a performance guarantee
Temperature uniformity, auxiliary consumption, leak control, ambient capacity, redundancy and maintenance determine actual results.
Continue the cabinet review
Connect the exact model to C&I system and BOM responsibilities
Use the storage solution and BOM guide to close interfaces before commercial comparison.
Commercial solar and storage solution
Define PV, storage, grid, backup, EMS, protection, site and commissioning as one project scope.
Review C&I storage scope →Solar and storage BOM review
Fix model codes, included equipment, interfaces, accessories, spares and exclusions before comparing quotations.
Review the cabinet BOM →G125K-LE260 FAQ
Questions to close before commercial release
The exact cabinet model still needs a released BOM and project performance basis.
Is 261 kWh the usable AC energy?
No. It is nominal energy. Confirm the warranted usable DC/AC energy after SOC reserve, DoD, losses, auxiliary loads, temperature, power level and degradation.
Why are both 125 kW and 130.5 kW shown?
The record uses 125 kW AC system-class and 130.5 kW DC rated-power wording. Require a released datasheet/BOM that maps both to the same configuration before quoting performance.
Does aerosol fire protection establish site compliance?
No. Confirm the detailed detection/suppression design, standards/tests, ventilation and shutdown logic, alarms, emergency interface and local authority approval.
Which acceptance tests are needed?
Define document review, FAT, delivery inspection, installation checks, SAT, controls/protection tests, usable-energy/RTE or capacity tests, training and final handover.
Prepare a G125K-LE260 project RFQ
Send the duty profile, required usable energy and kW, AC/grid interface, site climate/layout, fire requirements, logistics and performance-acceptance criteria.
Start with the product, application or project information you have. We can help identify the remaining configuration, document or delivery questions before a final quotation.
Verify the Cabinet ScopeRelated Products

GCB-E50 50kW / 50kWh C&I Energy Storage Cabinet
50 kW rated charge and discharge power / 50 kWh nominal system energy air-cooled commercial & industrial energy storage cabinet for small commercial self-consumption, demand management and backup projects.
View Details
GCB-E100 50kW / 100kWh C&I Energy Storage Cabinet
50 kW rated charge and discharge power / 112.53 kWh / 100.35 kWh, depending on the selected 314 Ah / 280 Ah battery option air-cooled commercial & industrial energy storage cabinet for c&i peak shaving, solar self-consumption and backup support.
View Details
GCB-E240 125kW / 241kWh C&I Energy Storage Cabinet
125 kW rated charge and discharge power / 241.15 kWh / 215.04 kWh, depending on LFP battery option air-cooled commercial & industrial energy storage cabinet for commercial peak shaving, solar-plus-storage and demand-charge management.
View Details