SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU-SM2-P
Hybrid InverterSingle Phase Low Voltage Hybrid Inverter3.6-10kW

SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU-SM2-P

Single Phase Hybrid Inverter | 3.6-10kW | | 2 MPPT | LV Battery Supported

Single Phase Hybrid Inverter3.6-10kW2 MPPTLV Battery Supported
Send Inquiry

Overview

SUN-3.6/5/6/7/7.6/8/10K-SG05LP1-EU-SM2-P Single Phase Hybrid Inverter | 3.6-10kW | | 2 MPPT | LV Battery Supported

Product Highlights

Features

Colorful touch LCD, IP65 protection degree
01

Colorful touch LCD, IP65 protection degree

AC couple to retrofit existing solar system
02

AC couple to retrofit existing solar system

Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries in parallel
03

Max. 16 pcs parallel for on-grid and off-grid operation; Support multiple batteries in parallel

Max. charging/discharging current of 210A
04

Max. charging/discharging current of 210A

05

6 time periods for battery charging/discharging

06

Support storing energy from diesel generator

Specifications

ModelSUN-3.6K-SG05LP1-EU-SM2-PSUN-5K-SG05LP1-EU-SM2-PSUN-6K-SG05LP1-EU-SM2-PSUN-7K-SG05LP1-EU-SM2-PSUN-7.6K-SG05LP1-EU-SM2-PSUN-8K-SG05LP1-EU-SM2-PSUN-10K-SG05LP1-EU-SM2-P
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range(V)40-60
Max.Charging Current(A)90120135175190190210
Max.Discharging Current(A)90120135175190190210
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of battery input1
PV String Input Data
Max. PV Access Power (W)7200100001200014000152001600020000
Max PV Input Power(W)57608000960011200121601280016000
Max PV Input Voltage(V)500
Start-up Voltage(V)125
MPPT Voltage Range(V)150-425
Rated PV Input Voltage(V)370
Max Operating PV Input Current(A)18+1832+32
Max Input Short-Circuit Current(A)27+2748+48
No.of MPP Trackers/No.of String Per MPP Tracker2/1+12/2+2
AC Input/Output Data
Rated AC Input/Output Active Power(W)36005000600070007600800010000
Max AC Input/Output Apparent Power (VA)39605500660077008360880011000
Rated AC Input/Output Current(A)16.4/15.722.8/21.827.3/26.131.9/30.534.6/3336.4/34.845.5/43.5
Max AC Input/Output Current(A)18/17.325/2430/28.735.0/33.538/36.440/38.350/47.9
Max Continuous AC Passthrough (grid to load)(A)354050
Peak Power (off-grid)(W)2 times of rated power,10s
Rated Input/Output Voltage/Range(V)220V/230 0.85Un-1.1Un
Grid Connection FormL+N+PE
Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Power Factor Adjustment Range0.8 leading-0.8lagging
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5%ln
Efficiency
Max Efficiency97.6%
Euro Efficiency96.5%
MPPT Efficiency>99%
Equipment Protection
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface
Communication InterfaceRS485/RS232/CAN
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity0~100%
Permissible Altitude2000m
Noise<45
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm]366×589.5×237 (Excluding Connectors and Brackets)
Weight[kg]26.8
Warranty5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of CoolingIntelligent air cooling
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2