Offline UPS 650va 800va 1000va 1200va 1500va 2000va 50HZ/60HZ for Pc Computer
Offline UPSModel evidence review

Techfine 650 VA / 360 W Offline UPS Table Within a 650–2000 VA Source Title

The source title lists 650, 800, 1000, 1200, 1500 and 2000 VA, but the embedded parameter table specifies only a 650 VA/360 W offline UPS. That table describes 220 VAC input, 145–280 VAC mains range, modified-sine-wave battery output, less-than-6 ms transfer, one 12 V/7.2 Ah battery and six-hour charging to 90% under its stated condition. Separate current model sheets are required for every other rating named in the title.

Embedded table capacity: 650 VA / 360 W
Source title range: 650–2000 VA (only 650 VA table displayed)
Displayed battery-mode waveform: Modified sine wave
Displayed battery: 1 × 12 V / 7.2 Ah
Build Your RFQ

Original source record: Offline UPS 650va 800va 1000va 1200va 1500va 2000va 50HZ/60HZ for Pc Computer.

Current source parameter table

This table is preserved from the current source record. Read it with the identity, compatibility and document boundaries below; unresolved conflicts are not corrected by assumption.

Model650VA
Capacity650VA /360W
Input
Voltage220VAC
AC Mains Input Voltage Range145-280 VAC (same as AC mains)
Frequency50 Hz
Output
Voltage Range(Battery Mode)±10%
Frequency Range(Battery Mode)50 Hz ±1 Hz
Transfer Time<6ms
Waveform(Battery)Modified sine wave
Battery
Battery Type & Quantity12V7.2Ah x 1
Battery Charging Tiime6 hours charge to 90%
LED Indicators
AC ModeGreen light
Battery ModeRed light flash
Audible Alarm
Battery ModeAlarm beeps every six seconds
Low BatteryAlarm beeps every second
OverloadAlarm beeps twice every second
FaultAlarm beeps continuously
Protection Function
Comprehensive ProtectionOverload, deep discharge and over-charge protection
Environment
Temperature And HumidityRelative humidity 0-90% and temperature 0- 40°C (No-condensing)
Noiseless than 40dB at one meter distance
Physical Function
Dimensions (mm)335*87*143
Net Weight (kgs)4.6

Current document status

The current source record has one embedded 650 VA table and no downloadable model-specific datasheet. Request the full model code, nameplate and a separate current data sheet for each rating proposed in a quotation.

Current 650 VA table

Use the embedded 650 VA data only for the corresponding exact model

The broad source title does not create verified specifications for the other listed VA classes.

Displayed capacity

The embedded table states 650 VA/360 W. It does not show model-specific electrical or battery rows for 800, 1000, 1200, 1500 or 2000 VA.

Displayed AC behavior

The table shows 220 VAC, 145–280 VAC input range, 50 Hz battery output, ±10% battery-mode voltage and less-than-6 ms transfer. Confirm the regional version and test condition.

Modified-sine battery output

Load compatibility must be checked with the actual PSU, transformer, motor or peripheral; a PC-oriented title does not approve every office device.

Displayed battery

One 12 V/7.2 Ah battery and six hours to 90% charge are listed. Confirm included battery make/model, charger, cutoff, replacement route and runtime at the real combined load.

650 VA offline UPS RFQ checks

Six checks before selecting this record for PC or office backup

The final quotation must identify one exact model and the devices expected to ride through its transfer event.

Exact model and rating

Request the complete model code, nameplate, 650 VA/360 W confirmation and separate data for any alternate rating; prohibit silent substitution between title variants.

Protected equipment

List PC, monitor, router, POS and peripherals with normal/peak W and VA, active-PFC or transformer details, inrush and equipment excluded from the UPS.

Waveform acceptance

Confirm that each powered device accepts modified-sine-wave battery output and document any manufacturer requirement for pure sine wave or maximum transfer duration.

AC and outlets

Confirm destination voltage/frequency, plug and outlet count/type, grounding, input window, cold start, restart, return-to-mains behavior and local electrical evidence.

Battery and runtime

Confirm exact battery, Ah, inclusion, charger and cutoff; request runtime at the stated total W load and temperature rather than treating VA as operating time.

Generator, evidence and terms

Provide generator voltage/frequency/THD if used; request manual, safety/EMC evidence, warranty, accessories, sample, quantity, lead time and substitution control.

Range and load boundaries

A 650–2000 VA title does not establish six validated UPS models

Only the 650 VA table is currently visible, and even that table needs a complete model identity.

Do not extrapolate the range

Battery quantity, W rating, charger, size, outlets and transfer behavior for other VA classes must come from their own current model sheets.

Modified sine wave is not universal

Active-PFC supplies, transformers, motors, audio and medical equipment can have additional waveform requirements. Obtain load acceptance and test where needed.

Less than 6 ms is not zero transfer

Confirm whether every target device rides through the actual event, including low battery, overload, cold start and return-to-mains conditions.

Generator compatibility is conditional

Generator size, voltage/frequency regulation, waveform THD, neutral/grounding and the UPS input window determine whether the pairing operates correctly.

Continue the offline UPS review

Define critical office loads and a transparent runtime basis

Use these pages to keep essential equipment and autonomy assumptions explicit.

Techfine 650 VA offline UPS FAQ

Questions created by the broad title and single parameter table

The answers prevent the 650 VA table from being copied across unverified models.

Does this page verify 650–2000 VA Techfine UPS models?

No. Its current embedded table specifies only 650 VA/360 W. Request separate current data sheets and exact model codes for any other VA rating.

Will the modified-sine output work with every PC?

Do not assume so. Confirm the PSU and active-PFC requirements, normal/inrush demand, waveform tolerance and transfer ride-through for every powered device.

Does less-than-6 ms mean no interruption?

No. It is a source value without full test detail, not zero transfer. Confirm the condition and test the target equipment where continuity matters.

What should be requested before ordering?

Obtain the exact model/nameplate, current datasheet/manual, output and outlet version, battery/charger/runtime data, waveform and transfer evidence, safety/EMC documents, warranty and terms.

Request an exact 650 VA offline UPS quotation

Send the protected devices, W/VA/inrush, waveform and transfer tolerance, destination AC/outlets, runtime target and generator details. Require an exact model sheet and nameplate.

Verify 650 VA Model
Chat with Us